Energy

Generation, storage and energy management, sized from measured data.

Start a project

Overview

Logicode designs solar generation, battery storage and building energy management from measured consumption, and reports every installation against its forecast.

In brief Electricity is a bill, a risk and an opportunity. We measure how a site uses it, then design solar, batteries and controls so it costs less and doesn't go dark.

Capabilities

Three core capabilities.

Solar PV and battery storage

Logicode designs solar generation and battery storage sized from measured load data, including backup supply for essential circuits.

In brief Panels on the roof, batteries in the plant room, and power that stays on when the grid doesn't.

Technical detail
  • Grid-tied, hybrid and off-grid solar PV
  • LiFePO4 storage sized to the critical load
  • Changeover in milliseconds, with a small UPS for IT

Building energy management

Energy management systems are specified and commissioned to control HVAC, lighting and pumping according to measured occupancy and demand.

In brief A system that runs the air conditioning, lights and pumps according to who is actually in the building.

Technical detail
  • BEMS over BACnet, Modbus and KNX
  • Sub-metering per floor, tenant or circuit
  • Schedules tied to occupancy and weather

As-built records and BIM

Electrical and control installations are documented in a building information model, giving the operator an accurate record of every asset.

In brief A 3D model that shows where every cable, meter and controller is.

Technical detail
  • BIM in IFC and Revit
  • COBie asset data for facilities teams
  • As-built drawings kept current

Architecture

How it fits together.

DCACPV arrayStrings, DC isolatorsHybrid inverterMPPT, AC conversionDistribution boardProtection, changeoverLoadsEssential and generalBatteryLiFePO4 with BMSGrid or generatorThrough a revenue meterEnergy managementMonitoring, scheduling
Figure. Site power architecture with solar, storage and a grid connection
Connections as a table
FromToConnection
PV arrayHybrid inverterDC
Hybrid inverterDistribution boardAC
Distribution boardLoadsWired connection
BatteryHybrid inverterWired connection
Grid or generatorDistribution boardWired connection
Energy managementBatteryData or radio link
Energy managementGrid or generatorData or radio link

Solid line: wired connection. Dashed line: data or radio link.

Delivery method

Four stages, each with a defined output.

  1. 01

    Load survey

    Electrical demand is logged at the main incomer and the principal circuits for at least seven days.

    In brief A week of measurements shows when and where the power goes.

    Technical detail

    Logging meters on the incomer and the main circuits, and a list of the loads that must survive an outage.

  2. 02

    System design

    Array, inverter and battery capacities are calculated together from the logged data and the client's backup requirement.

    In brief Panels, inverter and batteries sized together, from that data.

    Technical detail

    Array kWp from irradiance and performance ratio; battery kWh from critical load × hours ÷ usable depth; inverter sized for motor start surge.

  3. 03

    Installation and commissioning

    The installation is built to the approved drawings and tested against a commissioning schedule before handover.

    In brief Built to the drawings and tested before handover.

    Technical detail

    Protection settings, changeover tests, string checks and a commissioning report.

  4. 04

    Performance reporting

    Generation, consumption and savings are reported monthly against the figures stated in the design.

    In brief Monthly numbers show whether it does what we said it would.

    Technical detail

    Remote monitoring of inverter, battery and meters; yield against the design estimate; alerts for the obvious faults.

Technical specification

Standards, components and tools.

The components, standards and tools Logicode works with most often. Existing site equipment outside this list is accommodated.

AreaWhat we use
GenerationGrid-tied, hybrid and off-grid solar PV; generator integration
StorageLiFePO4 battery systems, hybrid inverters
ControlsBEMS over BACnet, Modbus, KNX and DALI
MeteringSub-metering, power-quality analysers, prepaid and smart meters
RecordsBIM (IFC, Revit), COBie, as-built drawings

Deliverables

What the client receives.

  1. 01

    Load survey report

  2. 02

    System design with sizing calculations

  3. 03

    Single-line diagrams and installation drawings

  4. 04

    Commissioning test records

  5. 05

    Building information model of the installation

  6. 06

    Monthly performance reports

Example scenario, not a client project

An office that rides through power cuts

A 40-person office loses half a day's work every time the grid drops, and runs a diesel generator most weeks.

  1. Energy

    An 11 kWp array and 18 kWh of batteries on the critical circuits.

  2. Electronics

    A sub-metering panel on the main distribution boards.

  3. Software & AI

    A dashboard comparing solar output with the design estimate.

Servers and lights stay on through six-hour outages, and the generator runs a few hours a month instead of a few hours a week.

Next

Software & AI

Continue scrolling to proceed, or select the title.