Data Centres & Telecom
Overview
Logicode provides power, cooling and environmental monitoring, backup systems and network design for server rooms, data centres and telecom sites.
In brief A server room fails in predictable ways. We put sensors on its power and cooling so you hear about trouble before the room goes down.
Disciplines
The engineering disciplines involved.
- 01EnergyGeneration, storage and energy management, sized from measured data.→
- 02Wireless & IoTWireless connectivity engineered for the site: range, interference and service life.→
- 03Software & AIApplications, data platforms and AI, deployed where the organisation requires.→
- 04ElectronicsPrinted circuit assemblies and embedded firmware, designed for volume manufacture and field service.→
Priorities
Three priorities for the sector.
Power chain monitoring
Every stage of the supply, from the utility incomer to the rack, is metered and alarmed.
In brief Every step from the grid to the rack, watched.
Technical detail
- UPS, generator and battery monitoring
- Rack-level metering and PUE
- Automatic generator test logs
Cooling and environmental monitoring
Temperature and humidity are monitored at the rack, with alarms raised on a rising trend as well as on fixed limits.
In brief An alarm when a room starts warming up, not when it's already too hot.
Technical detail
- Temperature and humidity per aisle
- Leak detection under raised floors
- Cooling unit status
Remote site telemetry
Tower and edge sites report power, environmental and access status to a central operations view.
In brief Tower and edge sites that report their own faults.
Technical detail
- Monitoring over the site's own cellular link
- Fuel, battery and door sensors
- Fault alerts that name the part needed
Architecture
How it fits together.
Connections as a table
| From | To | Connection |
|---|---|---|
| Utility feed | UPS | Wired connection |
| UPS | Power distribution | Wired connection |
| Power distribution | Racks | Wired connection |
| Generator and battery | UPS | Wired connection |
| Monitoring | Power distribution | Data or radio link |
Solid line: wired connection. Dashed line: data or radio link.
Example scenario, not a client project
A tower site that asks for the right part
Technicians drive four hours to a remote tower, only to find they brought the wrong spare.
- Energy
Battery and generator monitoring on site.
- Wireless & IoT
Data sent over the tower's own cellular link.
- Software & AI
An alert that names the fault and the part to bring.
Fewer wasted trips, and most faults fixed on the first visit.