Data Centres & Telecom

Monitoring and backup for power and cooling.

Start a project

Overview

Logicode provides power, cooling and environmental monitoring, backup systems and network design for server rooms, data centres and telecom sites.

In brief A server room fails in predictable ways. We put sensors on its power and cooling so you hear about trouble before the room goes down.

Priorities

Three priorities for the sector.

Power chain monitoring

Every stage of the supply, from the utility incomer to the rack, is metered and alarmed.

In brief Every step from the grid to the rack, watched.

Technical detail
  • UPS, generator and battery monitoring
  • Rack-level metering and PUE
  • Automatic generator test logs

Cooling and environmental monitoring

Temperature and humidity are monitored at the rack, with alarms raised on a rising trend as well as on fixed limits.

In brief An alarm when a room starts warming up, not when it's already too hot.

Technical detail
  • Temperature and humidity per aisle
  • Leak detection under raised floors
  • Cooling unit status

Remote site telemetry

Tower and edge sites report power, environmental and access status to a central operations view.

In brief Tower and edge sites that report their own faults.

Technical detail
  • Monitoring over the site's own cellular link
  • Fuel, battery and door sensors
  • Fault alerts that name the part needed

Architecture

How it fits together.

Utility feedIncoming supplyUPSConditioning, ride-throughPower distributionMetered PDUsRacksServers, network, coolingGenerator and batteryChangeover, autonomyMonitoringPower, temperature, alarms
Figure. Power chain to the rack, with monitoring
Connections as a table
FromToConnection
Utility feedUPSWired connection
UPSPower distributionWired connection
Power distributionRacksWired connection
Generator and batteryUPSWired connection
MonitoringPower distributionData or radio link

Solid line: wired connection. Dashed line: data or radio link.

Example scenario, not a client project

A tower site that asks for the right part

Technicians drive four hours to a remote tower, only to find they brought the wrong spare.

  1. Energy

    Battery and generator monitoring on site.

  2. Wireless & IoT

    Data sent over the tower's own cellular link.

  3. Software & AI

    An alert that names the fault and the part to bring.

Fewer wasted trips, and most faults fixed on the first visit.

Next

Research

Continue scrolling to proceed, or select the title.